DOCUMENTATION PDFs

No documents available

  • PowerCap PFC

    Normal and fixed loads

    Specs

    Compensation type
    Fixed capacitor

    Capacity
    2.5 – 150 kvar

    Nominal voltage
    480V-600V*

    Maximum steps
    1

    Network harmonics
    Low network harmonics

    Load characteristics
    Fixed

    Fusing
    Fuseless base configuration

    Power factor controller
    None

    Operating Temperature (C/F)
    -40° to 46° / -40° to 115°

    Enclosure rating
    NEMA 1

    Mounting
    Floor or wall mount

    Options

    208/240 V

    NEMA 3 outdoor rating

    Fuse and light configuration

  • PowerMVar

    Traditional Switching

    Specs

    Compensation type
    Fixed / Auto Filtered or Unfiltered

    Capacity
    500 kvar – 50 MVar+

    Voltage class
    5 – 38 kV

    Maximum steps
    12

    Network harmonics
    Low / High

    Load characteristics
    Fixed / Variable

    Switching Type
    None / Traditional

    Filter Tuning
    De-Tuned, Single-tuned, Multi-tuned, High pass, C-type

    Communication
    USB, Modbus, Ethernet, Profibus

    Operating Temperature (C/F)
    -40° to 50° / -40° to 122° without derating

    Enclosure rating
    NEMA 1/12/3R

    Options

    Smart Control Interface (SCI+)

    Main contactor

    Main disconnect / ground switch

    Protection relay
    (ANSI 27, 59, 50/51/51G, 49 and AFD, Ithd, Vthd)

    Power Quality metering

    NEMA 4X

    Arc Flash rated enclosure

    Arc Flash protection system

  • PowerVar PFC

    For low harmonics, variable loads

    Specs

    Compensation type
    Auto capacitor

    Capacity
    75 – 1200 kvar

    Nominal voltage
    480V-600V*

    Maximum steps
    12

    Network harmonics
    Low network harmonics

    Load characteristics
    Variable

    Switching Type
    Contactor

    Filter Tuning
    N/A

    Power factor controller
    Microprocessor-based with harmonic over current protection

    Operating Temperature (C/F)
    -40° to 115° /-40° to 46°

    Enclosure rating
    NEMA 1/12/3R

    Options

    208/240 V

    NEMA 4X

    Blown fuse indicator

    Modbus, Ethernet, and Profibus

    Capacitor life indicator

    Metering

    Amp meter and position selector

    Pilot lights

    Power on indicator

    GFI breaker

    On/Off selector switch

    Alarm

    Door switch

    Temperature alarm

  • PQube 3

    Power Analyzer

    Power analyzer, real time sensor and revenue meter. Monitors up to 2 three-phase loads, plus environmental and process parameters.

    Specs

    4-quadrant ANSI Class 0.2 revenue–grade energy

    2 three-phase loads or 8 single-phase loads

    Connects direct to voltages up to 690 V

    Class A IEC 61000-4-30 Ed3 certified

    Detects and records high-frequency impulses at 4 MHz

    Measures and records 2 kHz~150kHz emissions

    Monitors DC power and process parameters with 4 additional AC/DC analog channels

    32 GB internal flash memory

  • PowerCap Harmonic

    Moderate harmonics and fixed loads

    Specs

    Compensation type
    Fixed capacitor

    Capacity
    120 – 300 kvar

    Nominal voltage
    480V-600V*

    Maximum steps
    1

    Network harmonics
    Moderate network harmonics

    Load characteristics
    Fixed

    Fusing
    Fused and light configuration

    Power factor controller
    None

    Operating Temperature (C/F)
    -40° to 60° / -40° to 140°

    Enclosure rating
    NEMA 3R outdoor

    Mounting
    Floor or wall mount

    Options

    208/240 V

    Fuse less and power-on indicator

  • PowerVar Harmonic

    For moderate harmonics, variable loads

    Specs

    Compensation type
    Auto capacitor

    Capacity
    75 – 1200 kvar

    Nominal voltage
    480V-600V*

    Maximum steps
    12

    Network harmonics
    Low network harmonics

    Load characteristics
    Variable

    Switching Type
    Contactor

    Filter Tuning
    N/A

    Power factor controller
    Microprocessor-based with harmonic over current protection

    Operating Temperature (C/F)
    -40° to 115° /-40° to 46°

    Enclosure rating
    NEMA 1/12/3R

    Options

    208/240 V

    NEMA 4X

    Blown fuse indicator

    Modbus, Ethernet, and Profibus

    Capacitor life indicator

    Metering

    Amp meter and position selector

    Pilot lights

    Power on indicator

    GFI breaker

    On/Off selector switch

    Alarm

    Door switch

    Temperature alarm

  • PQube 3e

    Multiple load power quality monitoring

    Power analyzer, real time sensor and revenue meter. Monitors up to 4 three-phase loads, plus environmental and process parameters.

    Specs

    4-quadrant ANSI Class 0.2 revenue–grade energy

    4 three-phase loads, 14 single-phase loads or any combination

    Connects direct to voltages up to 690 V

    Class A IEC 61000-4-30 Ed3 certified

    Detects and records high-frequency impulses at 4 MHz

    Measures and records 2 kHz~150kHz emissions

    Monitors DC power and process parameters with 4 additional AC/DC analog channels

    32 GB internal flash memory

  • SynchroMVar

    Transient-Free Switching

    Specs

    Compensation type
    Fixed / Auto Filtered or Unfiltered

    Capacity
    500 kvar – 50 MVar+

    Voltage class
    5 – 38 kV

    Maximum steps
    12

    Network harmonics
    Low / High

    Load characteristics
    Fixed / Variable

    Switching Type
    Point on Wave (POW)

    Filter Tuning
    De-Tuned, Single-tuned, Multi-tuned, High pass, C-type

    Communication
    USB, Modbus, Ethernet, Profibus

    Operating Temperature (C/F)
    -40° to 50° / -40° to 122° without derating

    Enclosure rating
    NEMA 1/12/3R

    Options

    Smart Control Interface (SCI+)

    Main contactor

    Main disconnect / ground switch

    Protection relay
    (ANSI 27, 59, 50/51/51G, 49 and AFD, Ithd, Vthd)

    4X Enclosure Rating

    Power Quality metering

    Arc Flash rated enclosure

    Arc Flash protection system

  • PowerCap Filter

    High harmonics and fixed loads

    Specs

    Compensation type
    Detuned filter

    Capacity
    25 – 200 kvar

    Nominal voltage
    480V-600V*

    Maximum steps
    1

    Network harmonics
    High network harmonics

    Load characteristics
    Fixed

    Fusing
    Fused

    Power factor controller
    None

    Operating Temperature (C/F)
    -40° to 60° / -40° to 140°

    Enclosure rating
    NEMA 3R outdoor

    Mounting
    Floor or wall mount

    Options

    208/240 V

     

    Power-on light

    Blown fuse indicator light

  • PowerVar Filter

    For high harmonics, variable loads

    Specs

    Compensation type
    Auto filter

    Capacity
    75 – 1200 kvar

    Nominal voltage
    480V-600V*

    Maximum steps
    12

    Network harmonics
    High network harmonics

    Load characteristics
    Variable

    Switching Type
    Contactor

    Filter Tuning
    N/A

    Power factor controller
    Microprocessor-based with harmonic over current protection

    Operating Temperature (C/F)
    -40° to 115° /-40° to 46°

    Enclosure rating
    NEMA 1/12/3R

    Options

    208/240 V

    NEMA 4X

    Blown fuse indicator

    Modbus, Ethernet, and Profibus

    Capacitor life indicator

    Metering

    Amp meter and position selector

    Pilot lights

    Power on indicator

    GFI breaker

    On/Off selector switch

    Alarm

    Door switch

    Temperature alarm

  • PQube 3r

    Ultra accurate power analyzer and versatile controller

    Power analyzer, real time controller and revenue meter. Has 4 built-in programmable relay outputs that can be individually assigned to a specific disturbance.

    Specs

    4-quadrant ANSI Class 0.2 revenue–grade energy

    2 three-phase loads or 14 single-phase loads or any combination

    Connects direct to voltages up to 690 V

    Class A IEC 61000-4-30 Ed3 certified

    Detects and records high-frequency impulses at 4 MHz

    Measures and records 2 kHz~150kHz emissions

    Monitors DC power and process parameters with 4 additional AC/DC analog channels

    32 GB internal flash memory

  • PowerCap Auto

    Normal and variable loads

    Specs

    Compensation type
    Auto capacitor

    Capacity
    75 – 300 kvar

    Nominal voltage
    480V-600V*

    Maximum steps
    1-4

    Network harmonics
    Low network harmonics

    Load characteristics
    Variable

    Fusing
    1-4 steps with fusing

    Power factor controller
    Microprocessor-based with harmonic over current protection

    Operating Temperature (C/F)
    -40° to 55° / -40° to 131°

    Enclosure rating
    NEMA 1

    Mounting
    Wall mount

    Options

    208/240 V

    NEMA 3R outdoor rating

    Remote communication

    BFI fuse indicator

  • PowerVar Fast

    For high harmonics, variable loads

    Specs

    Compensation type
    Fast capacitor

    Capacity
    75 – 1200 kvar

    Nominal voltage
    480V-600V*

    Maximum steps
    12

    Network harmonics
    High network harmonics

    Load characteristics
    Dynamic

    Switching Type
    2 Phase Thyristor

    Filter Tuning
    3.78th

    Power factor controller
    Microprocessor-based with harmonic over current protection

    Operating Temperature (C/F)
    -40° to 115° /-40° to 46°

    Enclosure rating
    NEMA 1/12/3R

    Options

    208/240 V

    NEMA 4X

    Blown fuse indicator

    Modbus, Ethernet, and Profibus

    Capacitor life indicator

    Metering

    Amp meter and position selector

    Pilot lights

    Power on indicator

    GFI breaker

    On/Off selector switch

    Alarm

    Door switch

    Temperature alarm

  • PQube 3

    PQube 3v

    Voltage quality compliance

    Voltage compliance analyzer and real time sensor. Monitors the point of common coupling in facilities.

    Specs

    Voltage measurements

    N/A

    Connects direct to voltages up to 690 V

    Class A IEC 61000-4-30 Ed3 certified

    Detects and records high-frequency impulses at 4 MHz

    Measures and records 2 kHz~150kHz emissions

    Monitors DC power and process parameters with 4 additional AC/DC analog channels

    32 GB internal flash memory

  • PQube 3 Portable

    Power Analyzer

    Self-powered, ready-to-go portable kit designed for a quick install and temporary power measurement campaigns.

    Specs

    4-quadrant ANSI Class 0.2 revenue–grade energy

    Up to 2 three-phase loads

    Connects direct to voltages up to 690 V

    Class A IEC 61000-4-30 Ed3 certified

    Detects and records high-frequency impulses at 4 MHz

    Measures and records 2 kHz~150kHz emissions

    Monitors DC power and process parameters with 4 additional AC/DC analog channels

    32 GB internal flash memory