Easy to use, versatile, best price in its class

The PQube® 3 series of high-speed, revenue-grade power analyzers measure, identify, and record all power quality disturbance, and environmental process parameter data in real-time.  It connects directly to voltages up to 690 V and auto-configures by auto-detecting the mains frequency, wiring configuration and nominal voltage. The PQube 3 series boasts an impressive number of standard features including intuitive touch-screen display, up to 14 energy metering channels, 4-quadrant metering, alarms, and automatic reporting. The PQube 3 is made sturdy and compact, easily fitting into production equipment, data centers, rackmounts or harsh environments.

To get access to PQube 3 firmware, Modbus Client, Report Writer or for technical information, register on our portal.

Features

  • Auto-configures, it auto-detects the mains frequency, wiring configuration, and nominal voltage
  • Use on single or three-phase loads or a combination of loads
  • 4-quadrant ANSI Class 0.2 revenue–grade energy on 8 or up to 14 single-phase energy metering channels
  • Data accessible remotely or by user-defined image-based reports delivered by email
  • No software or transformer to install
  • An exhaustive array of inputs from electrical to environmental
  • Interface available in over 13 languages
  • Touch screen display and anti-tamper lid
  • 32 GB of internal flash memory holds years of data and events
  • Certified UL, CSA, ROHS, FCC, IEC, ANSI, TUV, and EMC compliant

Benefits

  • Versatile, use as power analyzer, controller, voltage monitor, and a revenue-grade meter
  • Get alerted to power, environmental, or process parameter symptoms before they happen
  • Monitors, records, and reports in real-time 24/7/365
  • Pinpoints the root cause of power quality or identifies unrelated issues
  • Installs anywhere, snap onto a DIN rail, pole mount, wall mount or rack mount
  • Reduce electricity costs and equipment failure
  • Reduce nuisance tripping or unexplained resetting of control devices
  • Use to accurately allocate electric rate structure costs in commercial buildings
  • Provides daily, weekly, or monthly understandable and actionable data, upon disturbance
  • FREE report writer companion software and Modbus real-time dashboard

Applications

  • Semi-conductor manufacturing and semi-conductor tools
  • Diagnostic imaging equipment systems in hospitals or health facilities
  • Data centers, telecom equipment and towers
  • Offshore platforms, marine vessels or remote operation vehicles
  • Airports and railway stations
  • Commercial and Industrial facilities
  • PQube 3

    Power Analyzer

    Power analyzer, real time sensor and revenue meter. Monitors up to 2 three-phase loads, plus environmental and process parameters.

    Specs

    4-quadrant ANSI Class 0.2 revenue–grade energy

    2 three-phase loads or 8 single-phase loads

    Connects direct to voltages up to 690 V

    Class A IEC 61000-4-30 Ed3 certified

    Detects and records high-frequency impulses at 4 MHz

    Measures and records 2 kHz~150kHz emissions

    Monitors DC power and process parameters with 4 additional AC/DC analog channels

    32 GB internal flash memory

  • PQube 3e

    Multiple load power quality monitoring

    Power analyzer, real time sensor and revenue meter. Monitors up to 4 three-phase loads, plus environmental and process parameters.

    Specs

    4-quadrant ANSI Class 0.2 revenue–grade energy

    4 three-phase loads, 14 single-phase loads or any combination

    Connects direct to voltages up to 690 V

    Class A IEC 61000-4-30 Ed3 certified

    Detects and records high-frequency impulses at 4 MHz

    Measures and records 2 kHz~150kHz emissions

    Monitors DC power and process parameters with 4 additional AC/DC analog channels

    32 GB internal flash memory

  • PQube 3r

    Ultra accurate power analyzer and versatile controller

    Power analyzer, real time controller and revenue meter. Has 4 built-in programmable relay outputs that can be individually assigned to a specific disturbance.

    Specs

    4-quadrant ANSI Class 0.2 revenue–grade energy

    2 three-phase loads or 14 single-phase loads or any combination

    Connects direct to voltages up to 690 V

    Class A IEC 61000-4-30 Ed3 certified

    Detects and records high-frequency impulses at 4 MHz

    Measures and records 2 kHz~150kHz emissions

    Monitors DC power and process parameters with 4 additional AC/DC analog channels

    32 GB internal flash memory

  • PQube 3

    PQube 3v

    Voltage quality compliance

    Voltage compliance analyzer and real time sensor. Monitors the point of common coupling in facilities.

    Specs

    Voltage measurements

    N/A

    Connects direct to voltages up to 690 V

    Class A IEC 61000-4-30 Ed3 certified

    Detects and records high-frequency impulses at 4 MHz

    Measures and records 2 kHz~150kHz emissions

    Monitors DC power and process parameters with 4 additional AC/DC analog channels

    32 GB internal flash memory

  • PQube 3 Portable

    Power Analyzer

    Self-powered, ready-to-go portable kit designed for a quick install and temporary power measurement campaigns.

    Specs

    4-quadrant ANSI Class 0.2 revenue–grade energy

    Up to 2 three-phase loads

    Connects direct to voltages up to 690 V

    Class A IEC 61000-4-30 Ed3 certified

    Detects and records high-frequency impulses at 4 MHz

    Measures and records 2 kHz~150kHz emissions

    Monitors DC power and process parameters with 4 additional AC/DC analog channels

    32 GB internal flash memory