We are pleased to announce that the latest version of PQView 4 and related components has been released and is available for download here.
The highlights we are most excited to share include:
- New, informative PQWeb error message system and account logout/timeout handling
- Added option to store email communication as .eml files
- PQube Data Handler: Added support for events in multi-feeder configurations
- Additional Data Handler fixes and improvements for PQube and IEC61850. See Release Notes for details.
- Multiple PQDR fixes and imporovements. See Release Notes for details.
Click here to download PQView 4.27.00 and associated documentation.
Release Notes
Version: 4.27
Date: 2026.05
[Core]
- [FEATURE] PQV-2673: PQDR startup with AS/SQL server handling improved
- [FIX] PQWEB-1282: PQDR Schedule ->Run Schedule: HTTP PUT command changed to POST in order to avoid common IIS configuration limitation.
- [FIX] PQView4SDKApplication up to date. Requires RELEASE build of PQViewDatalayer and dependencies copied to \Libs older
- [FEATURE] PQV-2813: PQDR SiteRecentData report – support for dynamic notification subject via {Title} token and notification priority based on categories with records.
- [FEATURE] PQV-2813: PQDR support for report/notification Title (->email Subject {Title} token) and Priority (->email MailPriority) values propagation defined in the ReportContent object
- [FEATURE] SUPPORT-1342: PQDR CompliaceCalculator(s) sets “Valid” flag to false in records that are flagged by an exclusion flagging (ie IEC61k430).
- [FEATURE] SUPPORT-1342: PQDR Flagging is checked for the entire interval of parameters like PLT (2h >10min)
- [FEATURE] SUPPORT-1342: PQDR IEC61k430 and NoVoltage flagging limits adjusted; flagging interval extended to after data gaps.
- [FIX] PQV-2812: PQDR EN50160 Vf1 and Vmsf parameters (compliance interval ISO year) shown as missing in weekly statistics issue fixed
- [FEATURE] PQDR: Support for embedded HTML report documents
- [FEATURE] PQV-2704: PQDR Site Recent Data Availability Report (PQDM import report equivalent)
- [FEATURE] PQWEB-1271 – PQDR Site Data availability report implementation
- [FIX] AdministrationService.CreateSiteGroup name URL decoding issue fixed
- [FEATURE] PQV-2781: Functionality to store outgoing emails to folder instead of sending through SMTP server supported via “dump://” prefix in the SMTP server setup
- [FEATURE] PQV-2793: L&G ADVANCE federated connection implementation
- [FEATURE] PQV-2784: COMTRADE 2013 export support added
- [FIX] SUPPORT-1279: FaultPoint notifications use buffered notifications property if available – preventing persistence delay issues
- [FEATURE] PQV-2777: PQDR reports: Auto(data-based) per site VLN/VLL channels selection implemented. Determined from availability of VLN/VLL non-frequency channels with QM=V.
- [FEATURE] PQV-2777: Support for LN/LL/Auto voltage type added to the PQDR Report page
- [FIX] PQV-2777: PQDR Compliance reports – scaling factor calculation fixed for Y connected meters used in VLL reports.
[Administration Service]
- [FIX] Corrected issue with the AS client that caused it only “fixup” the address of the first AS Server if multiple AS servers are specified.
- [FIX] IAdministrationService.cs missing document type categories calls added
- [FIX] PQV-2744: Document type with no categories specified check issue fixed.
- [FIX] PQV-2744 AS SQL UpdateDocumentTypeCategory and GetDocumentTypesByCategory check if category param is null
[PQWeb]
- [FEATURE] PQWEB-1286: “Show RMS Variations without Trends” option added to the Events page and reports – allows hiding RMS variations without RMS/Waveform records (e.g. Mag/Dur/Time PQDIF observation entries duplicating waveform data)
- [FIX] SUPPORT-1299: Fixed issues with interactive derived charts and export options with other minor fixes. – Added separate divs for regular charts and phasor charts. – Set visibility of all divs based on the chart type. – Updated display of error message when no chart is available. – Moved the toggle bar into a separate div linked to charts, so it only appears on regular charts and not on phasor charts.
- [FEATURE] PQV-2784: PQWebSDK – “Event/Trend/{connID:int}/{eventID:int}/{format?}” endpoint for exporting event stream (PQDIF, COMTRADE, CFF…) implemented
- [FIX] PQV-282: Fixed cropped export menu issue for interactive charts. The export menu now accommodates more items and displays scroll bars when needed.
- [FEATURE] PQWEB-1244: Added new and improved error handling for PQWeb features and workflows, including secure user logout handling where needed.
- [FEATURE] PQWEB-877: Added session timeout notification for inactive pages. Users are now notified before automatic logout due to inactivity.
[PQView Admin Website]
- [FEATURE] PQV-2793: AS Document editor – support for custom CSV/INI syntax coloring and schema validation
- [FEATURE] PQV-2794: Support for non-JSON AS Web Document editor and schema validation
- [FEATURE] PQV-2324: PQViewAdministrator – deleting or editing configuration documents triggers backup storage. Number of backups to keep is defined in AppSettings[“DocumentsBackupsKeep”]
- [FEATURE] PQV-2324 – Document backups for individual documents (and types -to show deleted documents) available for access in the Administrator Web.
[PQDMS]
- [FIX] PQube handler now downloads and remap channels of event files in multi-feeder (single voltage bus) confirmations.
- [FEATURE] PQV-2811: IEC61850 engine supports limiting parallel file downloads via IHlrIEC61850.dll.config IEC61850_ParalelFileDownloads appSettings key
- [FIX] CHttpClient now resets the “POST” information on each URL change. This ensures that information from a POST request is not preserved on the next request.
- [FEATURE] PQV-2782: IEC61850 DH support for file download only mode (Discovery\Disable IED Background Processing)
- [FIX] Revised CHttpClient to not reset connection options if keep-alive is enabled. This prevents unnecessary re-authentication on each request.
- [FEATURE] Added support for mapping PQube analog channels to digital threshold events. This functionality is required by CHEC.
- [FEATURE] PQV-2622: PQDMS EventCharacterizer + EventNotification analysis modules. Support for displaying per-phase RMS even duration via {Event._Event Duration From RMS AN…CA} properties and per-phase mag/dur statistics via {Event.perPhaseSummary} tokens
- [FEATURE] PQV-2798: PQDMS Category/Notification mechanism improvement – list of all in-range categories is generated by the Category and considered by EventNotification analysis modules in order to trigger notification dispatch for notifications without worst case but with one of matched categories enabled.
- [FEATURE] PQDMS Notification tokens: option to URL/HTML decode token replacements by adding “&” character at the end of the token name. For instance, “{category&}”==”U<90%” is replaced as “U<90%”.
- [FEATURE] AHlrCategoryHandler reports and AHlrEventNotification checks all Sag categories whose characteristics event mag/dur are matching.
- [FEATURE] PQV-1054: Additional DMS Event notification tokens added: For UTC timestamps: “{eventdateutc}”, “{eventtimeutc}”, “{eventtimeHMutc}”; for PQView (not DMS server) local: “{eventdatelocal}”, “{eventtimelocal}”,”{eventtimeHMlocal}”;
- [FIX] SUPPORT-1276: Revised to strip status character from the start of a time stamp in LDP files. Revised file processing logic to move or delete processed files even if they could not be successfully processed. This is required to prevent problematic files being processed on every poll.
- [FEATURE] PQV-2785: Added telnet setup to PQDMS configuration app.
- [FEATURE] PQV-2684: IEC61850 “DH. Keep Connection Open” preference added for continuous retrieval of RCB data
- [FIX] PQV-2684: IEC61850 DH. Socket-level 5s keep-alive pings disabled. Disabling all RCBs on the discovery tab disables background processing (periodic real time data meter connections)
- [FEATURE] SUPPORT-1314: ION DB DH case insensitive channel map support added by adding “=case-insensitive” (text) configuration file line.
- [FIX] SUPPORT-1301: PQDMS installer PQDMService.exe.config path normalization improved
- [FIX] PQV-2782: DMS crash caused by downloading many IEC 61850 meters fix. Download logging improved
- [FEATURE] PQV-2781: PQDMS SMTP client supports export to PickupDirectory .eml by using “dump://path-to-folder” instead of SMTP host